  • Fluke I2500 Flexible Current Probes, I2500-10 & I2500-18

    • 2500 A ac current measurement with select Fluke meters
    • Works with frequency, inrush, and min/max functions on select Fluke meters
    • Expands the measurement range to 2500 A ac while providing increased display flexibility, ability to measure awkward sized conductors and improved wire access
    • CAT IV 600V, CAT III 1000 V safety rating
    • 7.5 mm coil diameter allows measurement in tight spaces
    • Ergonomic allows easy operation with one hand
    • Three year warranty

    Learn More
  • Fluke I1730 - Flexible Current Probe in 12", 24", 36"

    The iFlex probes connect directly to the energy logger, displaying current measurements without error prone scaling factors. The 1.8 m (6 ft) cord allows separation between the measurement location and the energy logger making it easier to view the display. Fluke 1730 Energy Logger iFlex cables are available in 12, 24, and 36 inch models.

    Learn More
  • Fluke I400S AC Current Clamp

    • Companion to your scope or power quality meter to measure up to 400 A AC
    • Only current clamp available with a CAT IV 600 V / CAT III 1000 V safety rating
    • Specially designed to offer maximum utility in a compact shape
    • Take accurate current readings without breaking the circuit
    • Soft non-slippery overmold handle
    • Optional PM9081/001 BNC/Banana adapter for DMM's
    • Two ranges: 40 A and 400 A, 10 and 1 mV/Amp output
    • Max. conductor Ø 32 mm

     

    Learn More
    $699.00

  • Fluke I800 AC Current Clamp

    • Measures AC current from 100 mA to 800 A rms
    • 30 Hz to 10 kHz frequency range
    • CAT III 600 V rating
    • Accepts up to 54 mm (2.1 in) diameter conductor size
    • 1000:1 conversion factor for easy calculation
    • Rugged positive action design
    Learn More
    $799.00

  • Fluke I2000 - Flex AC Current Clamp

    The i2000 is an AC current probe utilizing the Rogowski principle. It can be used to measure currents up to 2000 A when used in conjunction with multimeters, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.

    • Three ranges: 20A, 200 A & 2000 A, 100 mV/A, 10 mV/A & 1 mV/A output
    • Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
    • Maximum conductor diameter 178 mm
    • CAT III 600 V safety rating

    Learn More
    $799.00

  • Fluke I310S AC/DC Current Clamp

    • Current Ranges: 30 A and 300 A ACRMS or ±45 A and 450 A DC
    • Measuring Ranges: ±45 A and 450 A dc
    • Output Sensitivity: 10 mV/A (40 A) to 1 mV/A (400 A)
    • Resolution: ±50 mA (40 A) to ±100 mA (400 A)
    • Load Impedance: > 10 k Ohms and £ 100 pF
    • Frequency Range (small signal): DC to 20 kHz (- 3 dB)
    • Phase Shift below 1 kHz, < 2 degrees
    • Temperature Coefficient: ±0.1% of reading / °C
    • Power Supply: 9 V Alkaline
    Learn More
    $899.00

  • Fluke I3000S Flex AC Current Probe in 24", 36"

    • Three ranges: 30A, 300A and 3000A, 1, 10 or 100 mV/A output
    • Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
    • Maximum conductor diameter 178mm
    • CAT III 600V safety rating
    • The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas
    Learn More
  • Fluke I1000S - 1000A AC Current Clamp-On Probe

    • Allows accurate measurement of currents from 100 mA to 1000 A rms, 5 Hz to 100 kHz without breaking into the circuit
    • A passive filter eliminates noise and ring on rapidly rising di/dt waveform, ensuring accurate screen displays
    • Connects directly to an oscilloscope through a reinforced coaxial cable and an insulated BNC connector
    • Can be used with multimeters with optional PM9081/001 BNC/Banana adapter
    • One year warranty
    Learn More
    $1,399.00

  • Fluke I6000S FLEX AC Current Probe, FLEX-36 & FLEX-24

    • Current Ranges 60 A / 600 A / 6000 A ACRMS
    • Output Sensitivity (AC coupled) 50 mV /5mV / 0.5mV per A
    • Load Impedance 100 kOhm minimum
    • Accuracy (at +25°C) ±1% of range (45 – 65 Hz)
    • Linearity (10% to 100% of range) ±0.2% of reading
    • Noise 8mV ACRMS (60 A) 2 mV ACRMS (600/6000A)
    • Frequency Range 10 Hz to 50 kHz (- 3 dB)
    • Phase Error < ±1º (45 – 65Hz), ±10º (at 20 kHz)
    • Position Sensitivity (with cable > 25mm from the coupling) ±2% of range
    • External field (with cable > 200mm from the head) ±1% of range
    • Power Supply 2 x AA MN 1500 LR6 alkaline 400 Hours, low battery indicator or dedicated ext power supply

    Learn More
  • Fluke 3140R - 400AMP Current Clamp

    • Current Range 2 A to 400 A
    • Accuracy 2 % RDG ± 0.04 A
    • Frequency Response 20 kHz
    • Jaw Opening 3.2 cm (1.25 in) dia.

    Learn More